Facade systems
Standard 60 mm
Featuring a 60-mm face width (inside and outside), WICTEC 60 is a stick system façade that meets the highest demands. With minor additions, WICTEC 60 fulfils the most exacting requirements with regard to burglar and bullet resistance and fire protection.
The advantages at a glance:
- Ideal for vertical façades and sloped-glazing and spatial-structure transitions
- Individual design thanks to a wide range of profile geometries for the supporting structure and glazing profiles
- Reliable glass load transfer (up to 4 kN), with adapted transom-joint technology
- Overlapping and secure drainage at the cross-over point, without mechanical mullion processing, ensures tried-and-tested impermeability
- Filigree look without any change in appearance to the inner mullion and transom gaskets
- High static value of profiles, with the additional option of inner strengthening
- Glazing from outside featuring single- and/or two-part pressure and cover profiles
- Design options with covered or visible screw fixings
- Extensive solutions for structure junctions and conservatories
Openable elements:
- WICLINE 60E, WICLINE 70E, WICLINE 77 and WICLINE 125 window ranges with visible and/or concealed sash as turn, turn/tilt, tilt and parallel sliding/tilt windows
- Skylight windows
- Parallel extender sash and top-hung windows
- Horizontally/vertically pivoted windows
- WICLINE 77 ventilation flap
- WICSTYLE 60E, WICSTYLE 70E, WICSTYLE 77, WICSTYLE 81 and WICSTYLE 88 single- and double leaf door ranges (can be opened inwards and outwards)
- WICSLIDE lifting/sliding doors and folding/sliding systems
Technical specifications:
| System width: |
60 mm |
| Profile depth: |
70-170 mm mullions |
| Thermal insulation: |
Uf to 1.2 W/m²K |
| Infill thickness: |
3-51 mm |
| Glass weight: |
up to 4 kN |
| Roof pitch: |
up to 10° |
If you have any further requirements, we will be pleased to provide you with individual solutions.
System tests/CE tests in accordance with EN 13830/approvals:
| Air permeability: |
class AE |
| Tightness against driving rain force: |
RE 1200 |
| Resistance to wind load: |
2000/-3200 Pa, security 3000/-4800 Pa |
| Shock resistance: |
E5/I5 |
| TRAV (Technical rules for using glazing to safeguard against falling): |
requirements met and guaranteed via approval |
| Approval in accordance with building regulations: |
for façade system, mullion-transom joints and for clamp connection (pressure-pad screw joint) |