Windows
System depth 65 mm
With
you have a universal system that fulfils all the requirements made of a modern window in an attractive design and economical construction. The advantages of WICLINE 65 are showcased in equal measure whether used in mullion-transom facades, as punch windows or as ribbon glazing. The flexibility accorded by multiple thermal insulation versions, the ability to select from various types of openings and fitting options and the ease with which safety functions can be added to the windows are supplemented by economical manufacture.
The advantages of WICLINE 65 at a glance:
- Minimised profile elevations
- Extensive choice of profiles for comprehensive range of applications
- Efficient thermal insulation: Uf values up to 1.5 W/m2K can be achieved, in the WICLINE 65 HI range an Uf value up to 1.4 W/m2K is attained
- Sashes with overlap, fitted flush or concealed
- Standard or concealed fittings
- For manual or motorised operation
- Simple to expand with intruder protection WK2/WK3 and bullet proofing FB4 S
- Can be constructed as natural smoke and heat exhaust ventilators
- Designs with rebated, inset and mounted drives possible
- Time-saving assembly thanks to straightforward corner connection, pre-mounted fitting components and user-oriented systems technology
- Based on the WICONA Unisys principle: great freedom of design, high process safety, cost and time saving, simple product, few tools required
Types of opening as integrated windows
- Turn sashes
- Turn/tilt sashes
- Tilt sashes
- Horizontally/vertically pivoted sashes
- Top-hung sashes
- Top-hinged/turn sashes opening outwards
Technical values:
|
Thermal insulation Uf frame: |
WICLINE 65: Uf up to 1.5 W/m2K WICLINE 65 HI: Uf up to 1.4 W/m2K |
hermal insulation Uw Window 1.3 x 1.8 m: 116 mm elevation width
|
Double glazing WICLINE 65: Uw = 1.5 W/m2K Double glazing WICLINE 65 HI: Uw = 1.4 W/m2K Triple glazing WICLINE 65: Uw = 1.3 W/m2K Triple glazing WICLINE 65 HI: Uw = 1.2 W/m2K |
| Sash weights: |
Standard: 100, 130 or 160 kg Concealed: up to 130 kg |
If you have further requirements we will be happy to provide you with an individual solution.
System inspections/CE product pass in accordance with EN 14351-1:
| Air permeability: |
4 |
| Ability to withstand heavy rainfall: |
Up to E900 |
| Ability to withstand wind: |
Up to C5 / B5 |
| Sound protection: |
Up to Rw = 45 (-2/-5) dB |
| Operating forces: |
1/2 |
| Load bearing capacity of safety measures: |
met |
| Mechanical strength: |
4 |
| Intruder resistance: |
Up to WK 3 |
| Bullet resistance: |
FB4 S |
External links
Examples